Copyright © 2010, Tjernlund Products, Inc. All rights reserved P/N 8504162
OWNER INSTRUCTIONS, DO NOT DESTROY
Recognize this symbol as an indication of important Safety Information!
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND
OPERATION OF THIS PRODUCT. READ THESE INSTRUCTIONS THOROUGHLY
BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW
THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUST-
MENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRI-
CAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL
INJURY OR PROPERTY DAMAGE.
!
DO NOT DESTROY. PLEASE READ CAREFULLY AND
KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
MODEL UCRT (UC1 with speed control)
INSTALLATION INSTRUCTIONS
REV. 1/10
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
UC1 VERSION
X.06
THE UCRT CONTROL IS ONLY SUITABLE FOR USE WITH
TJERNLUND RT SERIES ROOFTOP DRAFT INDUCERS
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - INSTALLATION INSTRUCTIONS

Copyright © 2010, Tjernlund Products, Inc. All rights reserved P/N 8504162OWNER INSTRUCTIONS, DO NOT DESTROYRecognize this symbol as an indication of

Pagina 2

9AlarmA Violet0.3 A, ACOIL VALVERABlueOrangeFFWhiteTBlackRed/WhiteT115 VACBURNER MOTORIGNITION TRANS500 VA10 FLA / 60 LRALine Voltage Thermostat60 HzS

Pagina 3

10UC1 UNIVERSAL CONTROL CONNECTED TO AN OIL-FIRED FURNACE WITH A HONEYWELL T87 OR EQUIVALENT NON-POWERED THERMOSTAT XNRUNIVERSAL CONTROLLERREMOVE JUMP

Pagina 4 - 4348657 35678 345678

11PSA-1 FAN PROVING SWITCH ADJUSTMENT NOTE: This section is also repeated in the Rooftop Inducer instruction manual.1. Drill an appliance draft sampl

Pagina 5 - 12 12 12 12

5. Activate burner(s) at full capacity. Gradually adjust balancing baffle(s) or speed control to maintain a slight negative draft (-0.02" to -0.0

Pagina 6 - TJERNLUND

13TROUBLESHOOTING ELECTRICAL PROBLEMSThe following guide is intended to be used if a problem occurs during the use of the Inducer and UC1. It may be

Pagina 7 - D/N 9183046-8

No voltage present from speed control: Replace UCRT Speed Control part number 950-8601.Voltage present from speed control: Confirm voltage is present

Pagina 8 - THERMOSTAT

WHAT IS NOT COVEREDProduct installed contrary to our installation instructions, altered, neglected or misusedProduct that has been wired incorrectlyPr

Pagina 9

1TABLE OF CONTENTSPage (s)Description and General Information...

Pagina 10 - UNIVERSAL CONTROLLER

23. All installation restrictions and instructions in the Inducer installation instructions must be adhered to when using the UC1.4. Make certain powe

Pagina 11 - D/N 9183046-2 10/16/03

LED STATUS INDICATORSLED #4 & #5 (Red) Flashing Alternately = Inducer in Pre-purge. (Pre-Purge options 0, 5, 20, 35 seconds)LED #4 & #5 (Red)

Pagina 12 - UNIVERSAL CONTROL

4UCRT INSTALLATIONDo not mount the UCRT junction box on a heat source that exceeds140oF (60oC). Examples of improper mounting surfaces include ventpi

Pagina 13 - 1 9

All wiring from the UC1 to the appliance must be appropriate Class 1 wiring as follows: installed in rigid metal conduit, intermediatemetal conduit, r

Pagina 14

6UC1 UNIVERSAL CONTROL CONNECTED WITH A 24 VAC ELECTRONIC IGNITION MODULEXNRUNIVERSAL CONTROLLERD/N 9183046-8115 VAC24 VACLEGEND:HONEYWELL IGNITIONCON

Pagina 15

7UC1 UNIVERSAL CONTROL CONNECTED WITH A SINGLE ZONE 24 VAC THERMOSTATXNRUNIVERSAL CONTROLLERTHERMOSTATGGINTERNAL CONTROLOF FURNACEWCYRRYAS APPLIANCE I

Pagina 16

8UC1 UNIVERSAL CONTROL CONNECTED TO A GAS OR OIL BURNER WITH AN AQUASTATXNRUNIVERSAL CONTROLLERLINE VOLTAGE OIL BURNERPRIMARY CONTROL, BURNERL1NXLJ1J2